Summary of 2005 PSC detention items (code 30)

Ship Name Type Flag Date Place Deficiencies
YANG QUAN Cargo Ship Panamanian 2005/11/11 Guangzhou
1.Quick close device for all oil tanks - Malfunction
2.Oil leakage alarm system for M/E Aux. engine - Malfunction
3.Hold of port venitiatin for E/R - Holed (20cm x 10cm)
KUO CHIA Container Carrier Chinese 2005/10/26 Osaka, Japan 1.Oily water separator oily dirty inside discharge pipe into the sea
2.Coalescer of O.W.S rotted
YM OCEAN Container Chinese 2005/10/03 Singapore
1.Lifeboat(Starboard) not able to start
BONANZA EXPRESS Cargo Ship Panamanian 2005/09/28 Osaka 1.Oily water separator (1)oily dirty inside of discharging pipe into the sea (2)Not working well
VALOUR Bulk Carrier Panamanian 2005/08/11 Varna, Bulgaria 1.Cargo ship safety equipment certificate -- Duration
2.Cargo ship safety construction certificate -- Duration
3.Cargo ship safety radio certificate - Duration
4.International oil pollution prevention certificate -- duration
5.Cleanliness of steering gear room
6.cleanliness of bilges in ER
7.Some of ship's charts for last/next voyage
8.All ship's charts for last/next voyage -- last NM No21-26.0505
ASIA CEMENT NO.1 Cement Carrier Chinese 2005/07/27 CHUBU, JAPAN
1.Oily water separator -- Not working in order
2.Inside of pipe line from oily water separator to bilge discharged over board valve -- dirty with sludge condition
CHC NO.1 Bulk Carrier Chinese 2005/07/20 Hong Kong 1.Quick closing valve of D.O. service tank found held in open position by a wood
2.Emergency fire pump found running without discharge pressure
3.Auto-closing door for access between engine room and steering gear room found held in open position by a steel wire
4.Nos. 1 & 6 units high pressure fuel protective pipes of main engine found not properly secured
5.Connection between main engine cylinder head and exhaust manifold of all units found not provided with insulation materials.
6.Several areas of the exhaust pipes of all generators found not provided with insulation materials.
7.Engine room funnel access to outside found with an additional locked steel grating.
8.Mushroom ventilator for galley found not possible to close
9.1 motorman's and chief cook's medical fitness certificates found expired.
10.ITU publications found outdated with version 2000 & 2001.
11.Starboard lifeboat found with the following defects (a)Aft floor plate found missing (b)Stanchions/supports for protective cover found not possible to fit to the boat (c)Limit switch for lifeboat davit found not working
12.Port lifeboat found with the following defects: (a)Floor plate in way of mast support plate found broken (b)Centre steel ring for holding the mast found with stuck stop pin (c)Limit switch for lifeboat davit found not working
JEANNIE III Bulk Carrier Panamanian 2005/06/29 KEELUNG 1.No.5 cargo hold watertight door hatch cover deformed and heavy corrosion and frame holed & corrosion
2.Lifeboat davit holed & corrosion
3.Air compressor room bulkhead holed & corrosion and door damaged
4.All of cargohold entrance hatch cover without screw
5.No.3 cargo hold crane post inside frame heavy corrosion
6.No.2 crane post full of oil inside
7.No.1 crane post full of water inside
8.No.1 cargo hold entrance deck holed and frame heavy corrosion
9.Bildge system out of function
10.Chain locker room full of water inside and bulkhead heavy corrosion
TAO YUAN Container Carrier Panamanian 2005/06/20 Hong Kong
1.Lifeboat hook release control rod/pope found the control pipe holed and defecting
2.Two ventilators at air pipes to under deck tanks found closing devices defective
3.Stbd lifeboat with all food ration found expired
4.Three places on plating found holed for engine room funnel
5.A small W.T. hatch on main deck to under deck at stern found holed
6.The batteries for GMDSS radio found dry and not ready for emergency use.
TONG HO Bulk Cement Chinese 2005/06/13 Hong Kong
1.Stbd lifeboat engine found could not be in idling engine condition
2.Inside paint locker, a non-explosive light found not working
3.One fire hydrant at E/R lower platform found its cover stuck in position
4.Air bottles for BA spares found they were mixed together for empty bottles & fully charged ones
5.One fire extinguisher in st'd lifeboat found discharged
6.SOLAS related operation drills found not comply with mandatory rules & regulation
WELLY Bulk Carrier Panamanian 2005/05/06 HONG KONG 1.Auto door closers missing(in)/ not work(NW) at following decks: Captain deck(M), Deck officer deck(NW) hospital deck(M) mess room deck(M)
2.6 lifejacket batteries for light not expiry dates
3.Port and starboard navigation light chocks broken/holed
4.MF/HF DSC no testing record and could not confirm transmission and receiving function
5.4 immersion suits broken/holed
6.Starbord lifeboat protective canopy to prevent crew from exposure to weather many broken holes, fire extinguisher empty,2x10 MJ food ration missing, propeller shaft bearing casing detached from boat structure and casing broken; Port lifeboat protective canopy to prevent crew from exposure to weather many broken holes, 4x10 MJ food ration missing
7.Many nautical publication outdated: china sea pilot Vol I 1987 amendment 2001 missing, China sea pilot vol II 1975 amendment 2004 missing, Bay of singal Pilot 1987 amendment Dec/2000 missing, Japan pilot vol I 1982n amendment Aug/2002 missing, Japan pilot vol III 1981 amendment Ict.2004 missing
EVER GOLDEN Container Chinese 2005/04/07 Hong Kong 1.Specific gravity of one set of batteries for emergency lighting found fallen into red region.
2.Jacketed piping system for high pressure fuel lines of main engine found not properly secured and plenty bolts and nuts found missing.
3.Some parts of exhaust pipes of all 3 generators found not provided with insulation material.
4.The following areas found very oily: (a)Floor plates below generators. (b)All 3 generators casing.
5.Engine room access hatch at main deck found with packing damaged and missing.
6.Emergency fire pump found without discharge pressure.
SHENG HO Cement Carrier Chinese 2005/03/31 Hong Kong 1.Auto door closers in vertical zone not working
2.Two generators(each 400kw)Hp fuel pipe not fitted with jacket and drain pipes
3.SB lifeboat protective cover to prevent crew from exposure big holes found
4.Three whistles for lifejacket not approval type
5.IAMSAR vol.III not onboard
6.Three portable GMDSS not working
SHENG LI Cargo Ship Panamanian 2005/01/07 Hong Kong 1.4 crewmember medical certificates expired(2004 April 12)
2.Batteries for lifejacket light no expiry date
3.SB lifeboat fire extinguisher missing
4.Port lifeboat no protective canopy and no sail
5.P and SB navigation light housing cracked in way of the chocks
6.Fireman outfits one explosion proof lamp was not working and the other was missing
7.P and SB generator exhaust pipes not insulated and hot parts exposed
8.Main engine HP jacketed fuel oil pipes were not properly fitted
9.Main engine exhaust pipe some parts exposed
10.Missing ITU publications(a)Ship stations (b)Manual for use by the maritime mobile and Martime Mobile-satellite service (c)Alpabetical list of call sign
EVER GIFTED Container Panamanian 2005/01/04 Hong kong 1.All life buoy light batteries found expired
2.Most of the life jacket light batteries found expired
3.One EEBD inside engine control room air pressure found fallen outside/below manufactures recommended limit
4.GMDSS MF/HF radio found not working properly
5.Port liferaft hydrostatic release found expired
6.Port lifeboat found with the follwing deficiencies (a)Mast base badly corroded (b)forward stanchion/support for protective gear found not possibility to fit
7.Emergency fire pump found without pressure
8.M.E. high pressure fuel protective pipe(all 6 units) not properly fitted
9.All 3 G/ES exhaust pipes 1.W.O. turbo charger connection not insulated
10.Fire damper of No.7(S) & No2(P) E/R ventilator found not working
11.Manhole cover I.W.O. funnel damper found open
KEN HO Cement Carrier Chinese 2005/01/03 Hong Kong 1.Deck isolating valves found seized
2.P+S lifeboats painter release handle sized
3.Obsolete muster lists were found in various position in the vessel
4.110v feeder panel in ECR insulation low
5.No non-slip floor in steering gear room